Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 235
Filtrar
1.
J Appl Oral Sci ; 32: e20230336, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38324805

RESUMO

OBJECTIVES: This study aimed to analyze the cost-effectiveness of whitening toothpastes and at-home bleaching for the treatment of tooth discoloration. METHODOLOGY: A cost-effectiveness economic analysis was conducted, and eight randomized clinical trials were selected based on the whitening agent product used: blue covarine dentifrices (BCD), hydrogen peroxide dentifrices (HPD), dentifrices without bleaching agents (CD, negative control), and 10% carbamide peroxide (CP10, positive control) for at-home bleaching. The consumer/patient perspective was adopted, macro-costing techniques were used and a decision tree model was performed considering the costs in the American and Brazilian markets. The color change evaluation (ΔE*ab) was used to calculate the effectiveness of tooth bleaching. A probabilistic analysis was performed using a Monte Carlo simulation and incremental cost-effectiveness ratios were obtained. RESULTS: CP10 resulted in the highest cost-effectiveness compared to the use of dentifrices in both markets. In Brazil, HPD was more cost-effective than BCD and CD. In the US, the increased costs of HPD and BCD did not generate any whitening benefit compared to CD. CONCLUSIONS: CP10 was more cost-effective than BCD and HPD for tooth bleaching from the perspectives of the Brazilian and American markets. Decision-making should consider the use of CP10 for treating tooth discoloration.


Assuntos
Clareadores Dentários , Clareamento Dental , Descoloração de Dente , Humanos , Cor , Análise de Custo-Efetividade , Dentifrícios/uso terapêutico , Peróxido de Hidrogênio/uso terapêutico , Clareamento Dental/métodos , Clareadores Dentários/uso terapêutico , Descoloração de Dente/tratamento farmacológico , Cremes Dentais/uso terapêutico , Ureia , Ensaios Clínicos Controlados Aleatórios como Assunto
2.
Pol Merkur Lekarski ; 51(5): 533-541, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38069855

RESUMO

OBJECTIVE: Aim: The objective of this study is to investigate the impact of professional teeth cleaning and the substances used in modern dentistry for whitening on the microelement composition of tooth enamel. PATIENTS AND METHODS: Materials and Methods: To study the morphology and microelement composition of the enamel, scanning electron microscopy was performed using the MiraLM microscope equipped with a Schottky field emission electron gun from Tescan. RESULTS: Results: A comparative analysis between the areas subjected to mechanical cleaning and those where it was not applied revealed a significant difference in the research results, particularly in carbon, which changed from 25.16±1.04 to 32.02±1.8. An analysis of the enamel's chemical composition before and after whitening revealed a decrease in carbon from 45.91±1.20 to 42.46±1.74. The change in phosphorus content was determined to be from 9.77±0.39 to 9.56±0.75. A decrease in calcium from 15.96±0.64 to 15.21±1.22 and magnesium from 0.07±0.01 to 0.01±0.01 was also observed. CONCLUSION: Conclusions: Professional dental hygiene does not have a direct impact on the microelement composition of enamel, such as the levels of calcium, phosphorus, fluoride, and other microelements. However, it can have an indirect and temporary influence due to the use of abrasive materials that affect dental deposits, pellicle, and the surface layer of enamel. Teeth whitening can affect the microelement composition of enamel, but these changes are mostly temporary and associated with processes of demineralization/ remineralization and oxygenation.


Assuntos
Clareadores Dentários , Clareamento Dental , Humanos , Clareamento Dental/métodos , Peróxido de Carbamida , Peróxido de Hidrogênio/farmacologia , Clareadores Dentários/uso terapêutico , Clareadores Dentários/farmacologia , Cálcio , Higiene Bucal , Fósforo , Carbono , Esmalte Dentário/química , Ureia/farmacologia
3.
Int J Periodontics Restorative Dent ; (7): s18-s25, 2023 10 24.
Artigo em Inglês | MEDLINE | ID: mdl-37879050

RESUMO

PURPOSE: To evaluate the effects of desensitizing MI Varnish (GC America) applied before or after bleaching on the mineral component of enamel and surface topography. MATERIALS AND METHODS: The coronal portions of 10 freshly extracted bovine teeth were segmented for a total of 40 specimens. Enamel specimens obtained from each tooth were randomly divided into four groups (n = 10): Group A = no bleaching; Group B = bleaching with 40% hydrogen peroxide (HP); Group C = MI Varnish applied before bleaching; and Group D = MI Varnish applied after bleaching. The calcium (Ca) and phosphorus (P) levels of the specimens in each group were determined by energy dispersive spectroscopy (EDS). Morphologic changes were observed using scanning electron microscopy (SEM). One-way ANOVA and Tukey HSD tests were used for statistical analyses (α = .05). RESULTS: The mean Ca content of Group B was significantly lower than those of Groups A, C, and D (P < .05). The mean Ca content of Group C was significantly lower than that of Group A (P < .05). There was no significant difference in Ca content between the other groups (P > .05). The mean P content of Group A was significantly higher than those of Groups B to D (P < .05). There was no significant difference in P content between Groups B to D (P > .05). CONCLUSIONS: Application of MI Varnish before or after in-office bleaching was effective in reducing mineral loss. However, applying MI Varnish after bleaching was more effective.


Assuntos
Clareadores Dentários , Clareamento Dental , Animais , Bovinos , Esmalte Dentário/química , Peróxido de Hidrogênio/farmacologia , Peróxido de Hidrogênio/uso terapêutico , Peróxido de Hidrogênio/análise , Minerais , Clareamento Dental/métodos , Clareadores Dentários/farmacologia , Clareadores Dentários/uso terapêutico , Clareadores Dentários/análise
4.
J Dent ; 139: 104744, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37852572

RESUMO

OBJECTIVE: To evaluate the effects of activated charcoal-based products used in two presentation forms (powder or toothpaste), compared to 10 % carbamide peroxide and conventional toothpaste on aesthetic perception and psychosocial impact before and after treatment. METHODS: Fifty-six participants were divided into 4 experimental groups (n = 14). Activated charcoal-based powder (PW); Activated charcoal-based dentifrice (AC); Conventional fluoride toothpaste (CD) and 10 % carbamide peroxide (CP). All products were used for 14 days. Psychosocial impact on dental esthetics (PIDAQ), oral health impact profile (OHIP- Esthetics) and orofacial esthetics scale (OES) questionnaires were applied before and after treatment. Descriptive and exploratory data analyses were performed and analyzed using linear mixed models for repeated measures over time considering significance level of α = 0.05. RESULTS: For PIDAQ, the CP group showed significant decrease in psychological impact, aesthetic perception domains and overall score, while in the PW group, there was only a significant decrease in the psychological impact domain. Decrease in OHIP was observed for the functional limitation domain scores for treatments with CP and PW, in the psychological discomfort domain, decrease was observed for all groups, while for the OES questionnaire, significant increase in the color domain was observed for the CP group. CONCLUSION: Activated charcoal-based products showed lower scores in all questionnaires when compared with carbamide peroxide; thus, charcoal-based products promoted lower impact on quality of life and aesthetic perception. CLINICAL RELEVANCE: In this randomized clinical trial, charcoal-based OTC products had inferior quality of life and aesthetic perception results compared to conventional carbamide peroxide bleaching.


Assuntos
Clareadores , Clareadores Dentários , Clareamento Dental , Humanos , Clareamento Dental/métodos , Peróxido de Carbamida , Carvão Vegetal/uso terapêutico , Clareadores Dentários/uso terapêutico , Estética Dentária , Qualidade de Vida/psicologia , Pós , Cremes Dentais , Percepção , Peróxido de Hidrogênio/uso terapêutico , Ureia/uso terapêutico , Peróxidos/uso terapêutico
5.
Oper Dent ; 48(6): 627-637, 2023 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-37881142

RESUMO

OBJECTIVES: The present study aimed to evaluate the desensitizing effect of toothpaste for sensitive teeth on patient tooth sensitivity and on bleaching efficacy of the 38% hydrogen peroxide bleaching agent used for in-office bleaching compared to a regular toothpaste in a randomized clinical trial. METHODS AND MATERIALS: Forty-eight patients having maxillary right central incisors with darkness greater than A1 were selected for the present double-blind randomized clinical trial. Patients were randomly allocated into two groups: the placebo group, which used regular toothpaste, and the experimental group, which used sensitivity toothpaste. The intervention consisted of applying toothpaste with the aid of an individual tray for a period of 4 minutes daily, starting one week before the first bleaching session and interrupting use immediately after the second session. After allocation to one of the groups, individuals received in-office dental bleaching with a 40-minute application of 38% hydrogen peroxide for two sessions with an interval of one week. The incidence and intensity of sensitivity were assessed using a visual analogue scale and a numeric analogue scale. Sensitivity was measured immediately before each session, 1 hour, 24 hours, and 48 hours after each bleaching session and four weeks after the second bleaching session. Tooth shade was evaluated using a spectrophotometer and by comparison with the VITA Classical Shade Guide (Vita Zahnfabrik, Bad Säckingen, Germany). Tooth shade was evaluated before the first bleaching session, one week after the first bleaching session, one week after the second bleaching session and four weeks after the second bleaching session. Participants and professionals who performed the bleaching, shade, and sensitivity assessments were blinded to the group of patients they were treating or assessing. For the incidence of hypersensitivity, the results were evaluated by comparing the groups at different evaluation times with the Mann-Whitney test for comparison between groups, the Friedman test for repeated measures, and the Tukey test for comparison of times. Shade change on the guide was analyzed using the Mann-Whitney test for comparison between groups and the Wilcoxon test for comparison between times. Shade change by the spectrophotometer was analyzed using the t-test for comparison between groups and the paired t-test for comparison between times. All analyses were performed with a significance level of 5%. RESULTS: There was no difference in the pattern of dental hypersensitivity between groups. For all shade measures, there was no difference between the bleaching results, and no statistically significant difference was observed between the study groups. CONCLUSION: The use of arginine-based desensitizing toothpaste did not interfere with the bleaching ability of hydrogen peroxide and was not effective in reducing the sensitivity caused by in-office tooth bleaching.


Assuntos
Sensibilidade da Dentina , Clareadores Dentários , Clareamento Dental , Humanos , Sensibilidade da Dentina/etiologia , Peróxido de Hidrogênio/uso terapêutico , Cremes Dentais/uso terapêutico , Clareadores Dentários/uso terapêutico , Clareamento Dental/efeitos adversos , Clareamento Dental/métodos , Resultado do Tratamento
6.
Clin Oral Investig ; 27(7): 3347-3361, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37273018

RESUMO

OBJECTIVES: The aim of this systematic review was to evaluate the prognosis of at-home dental bleaching using low concentration bleaching products. MATERIALS AND METHODS: This review was conducted was performed following the recommendations of the 2020 PRISMA statement and was registered in the International Prospective Register of Systematic Reviews (PROSPERO-CRD42022360530). The PICO question was "What is the prognosis of home teeth whitening treatment?". An advanced electronic search was made in three databases: PubMed, Web of Science, and Embase. RESULTS: The database search led to the retrieval of 225 articles. After elimination of duplicate references, the titles and abstracts of the articles were analyzed with respect to the eligibility criteria, and 24 studies were included for the development of the systematic review. CONCLUSIONS: Most authors state that the color remains stable between 1 and 2.5 years regardless of the type of bleaching agent or the forms of administration, and color stability in cases of severe discolorations presents a higher degree of recurrence. CLINICAL RELEVANCE: Given the growing demand for dental cosmetic treatments, the following systematic review may aid the clinician's continuing education and evidence-based practice by providing knowledge on the field of at-home dental bleaching agents and their long-term effects.


Assuntos
Clareadores , Clareadores Dentários , Clareamento Dental , Humanos , Peróxido de Hidrogênio/uso terapêutico , Clareadores Dentários/uso terapêutico , Clareamento Dental/métodos , Prognóstico
7.
Artigo em Inglês | MEDLINE | ID: mdl-37347995

RESUMO

This study aimed to clinically evaluate the effectiveness of two different at-home whitening protocols and to determine which is more effective: applying the whitening gel (16% carbamide peroxide) every 24 hours (Group A) or every 48 hours (Group B) for 2 weeks. Group C received a placebo gel (glycerin) without peroxide, which was applied every 24 hours for 2 weeks. The differences in terms of tooth sensitivity were also analyzed. A sample of 60 patients was divided into three groups of 20 patients. To compare the groups, color measurements were made using a spectrophotometer, and Student t test was used for independent samples. The confidence level was set at 95% (P ≤ .05). No statistically significant differences were found between Groups A and B (P > .05). The study concluded that 16% carbamide peroxide was equally effective when applied with either protocol and obtained the same results, but the 48-hour application protocol produced less sensitivity than the 24-hour application protocol.


Assuntos
Clareadores Dentários , Clareamento Dental , Humanos , Peróxido de Carbamida , Cor , Sensibilidade da Dentina/tratamento farmacológico , Peróxidos/uso terapêutico , Clareamento Dental/métodos , Clareadores Dentários/uso terapêutico
8.
Oper Dent ; 48(3): E71-E80, 2023 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-37079917

RESUMO

OBJECTIVE: The aim of this study was to compare the clinical efficacy of at-home, in-office, and combined bleaching regimens. METHODS: Forty-eight participants were recruited and randomly divided into four groups based on the bleaching regimen (n=12) as follows: 1) at-home bleaching using 10% carbamide peroxide (Opalescence PF 10%, Ultradent) for 14 days (HB); 2) two sessions of in-office bleaching using 40% hydrogen peroxide (Opalescence BOOST PF 40%, Ultradent) with a one-week interval (OB); 3) one session of in-office bleaching followed by at-home bleaching for seven days (OHB); and 4) at-home bleaching for seven days followed by one session of in-office bleaching (HOB). Tooth color was measured using a spectrophotometer (Easyshade, Vita ZahnFabrik) at baseline (T0), day 8 (T1), day 15 (T2), and day 43 (T3, four weeks after the end of the bleaching treatment). The color data were calculated using the CIEDE2000 (ΔE00) and whiteness index for dentistry (WID) formulas. Tooth sensitivity (TS) was recorded using a visual analogue scale (VAS) for 16 days. Data were analyzed by one-way analysis of variance (ANOVA) and the Wilcoxon signed-rank test (α=0.05). RESULTS: All bleaching regimens resulted in a significant increase in WID values (all p<0.05), while no significant differences in WID and ΔWID values were found among the different groups at each time point (all p>0.05). Significant differences in ΔE00 values were observed between T1 and T3 for all groups (all p<0.05), while no significant differences in ΔE00 values were found among the different groups at any time point (all p>0.05). Significantly lower TS values were observed in the HB group than in the OB and HOB groups (p=0.006 and p=0.001, respectively). CONCLUSIONS: All bleaching regimens resulted in great color improvement, and different regimens led to similar color changes at any of the evaluation time points. The sequence of treatments applying in-office bleaching or at-home bleaching did not affect the bleaching efficacy. The in-office bleaching and combined bleaching regimens yielded a higher intensity of TS than did at-home bleaching.


Assuntos
Sensibilidade da Dentina , Clareadores Dentários , Clareamento Dental , Humanos , Clareamento Dental/métodos , Cor , Peróxido de Hidrogênio/uso terapêutico , Peróxido de Carbamida/uso terapêutico , Resultado do Tratamento , Clareadores Dentários/uso terapêutico
9.
Hua Xi Kou Qiang Yi Xue Za Zhi ; 41(2): 190-196, 2023 Apr 01.
Artigo em Inglês, Chinês | MEDLINE | ID: mdl-37056185

RESUMO

OBJECTIVES: This study aimed to observe the color rebound and rebound rates of non-pulp discolored teeth within 1 year after routine internal bleaching to guide clinical practice and prompt prognosis. METHODS: In this work, the efficacy of bleaching was observed in 20 patients. The color of discolored teeth was measured by using a computerized colorimeter before bleaching; immediately after bleaching; and at the 1st, 3rd, 6th, 9th, and 12th months after bleaching. The L*, a*, and b* values of the color of cervical, mesial, and incisal parts of the teeth were obtained, and the color change amounts ΔE*, ΔL*, Δa*, and Δb* were calculated. The overall rebound rate (P*) and the color rebound velocity (V*) were also analyzed over time. RESULTS: In 20 patients following treatment, the average ΔE* of tooth color change was 14.99. After bleaching, the neck and middle of the teeth ΔE* and ΔL* decreased in the 1st, 3rd, 6th, 9th, and 12th months, and the differences were statistically significant. Meanwhile, from the 9th month after bleaching, the rebound speed was lower than that in the 1st month, and the difference was statistically significant. The incisal end of the tooth ΔE* and ΔL* decreased in the 6th, 9th, and 12th months after bleaching, and the differences were statistically significant. No significant difference was found in the rebound speed between time points. However, this rate settled after the 9th month, with an average color rebound rate of 30.11% in 20 patients. CONCLUSIONS: The results indicated that internal bleaching could cause a noticeable color change on pulpless teeth. The color rebound after bleaching was mainly caused by lightness (L*), which gradually decreased with time, and it was slightly related to a* and b*. The color of the teeth after internal bleaching rebounded to a certain extent with time, but the color rebound speed became stable from the 9th month. Clinically, secondary internal bleaching can be considered at this time according to whether the colors of the affected tooth and the adjacent tooth are coordinated and depending on the patient's needs.


Assuntos
Clareadores Dentários , Clareamento Dental , Descoloração de Dente , Dente não Vital , Dente , Humanos , Clareamento Dental/métodos , Dente não Vital/tratamento farmacológico , Cor , Descoloração de Dente/tratamento farmacológico , Peróxido de Hidrogênio/uso terapêutico , Clareadores Dentários/uso terapêutico
10.
Am J Dent ; 36(1): 44-52, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36917715

RESUMO

PURPOSE: This systematic scoping review aimed to survey the literature to answer the following questions: which instruments were used to measure the color change; which teeth were assessed for color; what was the follow-up period, and in which country was the recently published tooth bleaching clinical trial performed? METHODS: This research was registered in the Open Science Framework. The following databases were searched: PubMed, Scopus, Web of Science, EMBASE, Cochrane Library, and LILACS. Randomized clinical trials evaluating tooth bleaching with color change analysis, published between 2021 and 2017, were included. The data extracted from included studies were analyzed using a qualitative and descriptive analysis. RESULTS: 106 articles were analyzed. Most studies used only ΔEab to measure the color change (10.4%), assessed the color change in the maxillary central incisors (45.3%), and included a one-month follow-up (25.4%). The published papers were mostly from research performed in Brazil (51.9%). Many methods have been used in the tooth bleaching clinical trials examined, and a wide variety of instruments used to measure the color change was observed. CLINICAL SIGNIFICANCE: The large variation in the methodology criteria of most recent tooth bleaching clinical trials makes data comparison difficult among different studies and raises the need for a guideline for tooth bleaching clinical studies.


Assuntos
Sensibilidade da Dentina , Clareadores Dentários , Clareamento Dental , Dente , Humanos , Clareamento Dental/métodos , Clareadores Dentários/uso terapêutico , Peróxido de Hidrogênio/uso terapêutico , Sensibilidade da Dentina/tratamento farmacológico , Cor
11.
Oper Dent ; 48(3): 268-276, 2023 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-36929775

RESUMO

OBJECTIVES: To compare the bleaching efficacy and tooth sensitivity (TS) of 4% hydrogen peroxide (HP) in adults using a continuous or fractioned protocol. METHODS AND MATERIALS: A single-blind randomized controlled trial with a parallel design was conducted. Eighty-six patients with upper canines A2 or darker were submitted to bleaching with 4% HP gel for three weeks after random allocation into the fractioned protocol (two 30-minute daily applications) or continuous protocol (single one-hour application). We evaluated the color change at baseline, weekly, and 30 days after the bleaching using Vita Classical and Vita Bleachedguide using the units of shade guides (SGU) and by spectrophotometer using CIELab 1976 (ΔEab) and CIEDE 2000 formulas (ΔE00), as well as Whiteness Index (ΔWID). We assessed the absolute risk of TS with a visual analog scale (VAS) and numeric rating scale (NRS). Color changes in each recall were compared with the Student t-test. The risk of TS was evaluated by the Chi-square test, and the intensity by Mann-Whitney test (NRS) and Student t-test (VAS). RESULTS: The mean difference for the ΔSGU Vita Classical (0.5; 95% CI: -0.5 to 1.5), ΔSGU Vita Bleachedguide (-0.4; 95% CI: -1.5 to 0.7), ΔEab (1.4; 95% CI: -0.1 to 2.9), ΔE00 (0.6; 95% CI: -0.4 to 1.6), and ΔWID (-3.2; 95% CI: -7.3 to 0.9) after three weeks of bleaching was not clinically or statistically significant (p>0.10). The absolute risk of TS was 44% (95% CI: 30-58%) and 46% (95% CI: 32-61%) in the fractioned and continuous protocols, respectively (RR=1.0; 95% CI: 0.6 to 1.5; p>0.91). CONCLUSION: A fractioned bleaching protocol with 4% HP (30 minutes twice daily) did not increase the whitening degree nor affect the risk and intensity of TS when compared with the one-hour continuous protocol.


Assuntos
Sensibilidade da Dentina , Clareadores Dentários , Clareamento Dental , Humanos , Peróxido de Hidrogênio/uso terapêutico , Clareamento Dental/métodos , Clareadores Dentários/uso terapêutico , Sensibilidade da Dentina/induzido quimicamente , Método Simples-Cego , Resultado do Tratamento , Ensaios Clínicos Controlados Aleatórios como Assunto
12.
Int J Mol Sci ; 24(3)2023 Jan 19.
Artigo em Inglês | MEDLINE | ID: mdl-36768279

RESUMO

(1) This study investigated the whitening effect, cytotoxicity and enamel surface alterations induced by different over-the-counter (OTC) bleaching agents in comparison to hydrogen peroxide. (2) Human teeth (n = 60) were randomly assigned into 6 groups (n = 10), stained with coffee solution for 7 d, followed by a whitening period of 7 d with either placebo, bromelain, sodium bicarbonate, sodium chlorite, PAP or hydrogen peroxide. Color measurements were performed with a spectrophotometer. Scanning electron micrographs (SEM) were taken to assess the enamel structure. Cytotoxicity of the tested substances was assessed based on the cell viability of primary human fibroblasts. (3) The application of all whitening gels resulted in a greater color difference of the enamel (ΔE) in comparison to the negative control. Hydrogen peroxide caused the greatest color difference. Bromelain and PAP treatment showed no enamel surface changes, in contrast to hydrogen peroxide treatment, which showed very mild interprismatic dissolution. Bromelain was the only non-cytotoxic agent. (4) The maximum effect achieved by all OTC bleaching agents was the removal of stains, whereas hydrogen peroxide was capable of further whitening the teeth. Bromelain treatment was neither cytotoxic, nor resulted in enamel surface alterations, and its whitening effect was less, yet still effective, compared to hydrogen peroxide.


Assuntos
Clareadores Dentários , Clareamento Dental , Dente , Humanos , Peróxido de Hidrogênio/farmacologia , Clareadores Dentários/farmacologia , Clareadores Dentários/uso terapêutico , Bromelaínas , Clareamento Dental/efeitos adversos , Clareamento Dental/métodos , Cor
13.
J Am Dent Assoc ; 154(3): 245-259.e12, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36717350

RESUMO

BACKGROUND: Topical application of calcium-containing bioactive desensitizers (CBs) has been used to minimize bleaching-induced tooth sensitivity (TS). This study answered the research question "Is the risk of TS lower when CBs are used with dental bleaching in adults compared with bleaching without desensitizers?" TYPES OF STUDIES REVIEWED: The authors included randomized clinical trials comparing topical CB application with a placebo or no intervention during bleaching. Searches for eligible articles were performed in MEDLINE via PubMed, Cochrane Library, Brazilian Library in Dentistry, Latin American and Caribbean Health Sciences Literature, Scopus, Web of Science, Embase, and gray literature without language and date restrictions and updated in September 2022. The risk of bias was evaluated using Risk of Bias Version 2.0. The authors conducted meta-analyses with the random-effects model. The authors assessed heterogeneity with the Cochrane Q test, I2 statistics, and prediction interval. The authors used the Grading of Recommendations Assessment, Development and Evaluation approach to assess the certainty of the evidence. RESULTS: After database screening, 22 studies remained, with most at high risk of bias. No difference in the risk of TS was detected (risk ratio, 0.95; 95% CI, 0.90 to 1.01; P = .08, low certainty). In a visual analog scale, the intensity of TS (mean difference, -0.98; 95% CI, -1.36 to -0.60; P < .0001, very low certainty) was lower for the CB group. The color change was unaffected (P > .08). PRACTICAL IMPLICATIONS: Although topical CB dental bleaching did not reduce the risk of TS and color change, these agents slightly reduced the TS intensity, but the certainty of the evidence is very low.


Assuntos
Sensibilidade da Dentina , Clareadores Dentários , Clareamento Dental , Adulto , Humanos , Clareadores Dentários/uso terapêutico , Cálcio/efeitos adversos , Sensibilidade da Dentina/tratamento farmacológico , Brasil
14.
Clin Oral Investig ; 27(1): 69-78, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36512116

RESUMO

OBJECTIVES: Perform a systematic review to evaluate the influence of smoking on the effectiveness of tooth whitening (TW) and to analyze whether tooth sensitivity is different between smokers and non-smokers. MATERIALS AND METHODS: A systematic review modeled according to the PRISMA guidelines was conducted. PubMed, Embase, Web of Science, Cochrane, Scopus, and OpenGrey databases were searched for related clinical trials. The population, exposure, comparison, outcomes (PECO) was individuals who had TW performed, smoking individuals, non-smoking individuals, and effectiveness of TW, respectively. Risk of bias was assessed with the ROBINS-I tool, and data from included studies were extracted by two researchers independently. The certainty of the evidence was evaluated using the GRADE (Grading of Recommendations, Assessment, Development, and Evaluations) approach. RESULTS: Five studies were selected for qualitative analysis. The ROBINS-I tool classified 3 studies as having a moderate risk of bias, one study as having a serious risk of bias, and one with a critical risk. GRADE performed only for color change results and showed a low certainty of evidence. Limited evidence suggests that effectiveness of TW between smokers and non-smokers is similar. The tooth sensitivity also does not seem to be influenced by smoking. Due to the heterogeneity of the data, a meta-analysis could not be performed. CONCLUSIONS: Effectiveness of TW between smokers and non-smokers is comparable. The tooth sensitivity also does not seem to be influenced by smoking. CLINICAL RELEVANCE: The effectiveness of bleaching among smokers and non-smokers appears to be similar. Tooth sensitivity during TW also appears not to be influenced by smoking.


Assuntos
Sensibilidade da Dentina , Clareadores Dentários , Clareamento Dental , Humanos , Clareamento Dental/métodos , Clareadores Dentários/uso terapêutico , Sensibilidade da Dentina/tratamento farmacológico , Fumantes
15.
Artigo em Inglês | WPRIM (Pacífico Ocidental) | ID: wpr-981111

RESUMO

OBJECTIVES@#This study aimed to observe the color rebound and rebound rates of non-pulp discolored teeth within 1 year after routine internal bleaching to guide clinical practice and prompt prognosis.@*METHODS@#In this work, the efficacy of bleaching was observed in 20 patients. The color of discolored teeth was measured by using a computerized colorimeter before bleaching; immediately after bleaching; and at the 1st, 3rd, 6th, 9th, and 12th months after bleaching. The L*, a*, and b* values of the color of cervical, mesial, and incisal parts of the teeth were obtained, and the color change amounts ΔE*, ΔL*, Δa*, and Δb* were calculated. The overall rebound rate (P*) and the color rebound velocity (V*) were also analyzed over time.@*RESULTS@#In 20 patients following treatment, the average ΔE* of tooth color change was 14.99. After bleaching, the neck and middle of the teeth ΔE* and ΔL* decreased in the 1st, 3rd, 6th, 9th, and 12th months, and the differences were statistically significant. Meanwhile, from the 9th month after bleaching, the rebound speed was lower than that in the 1st month, and the difference was statistically significant. The incisal end of the tooth ΔE* and ΔL* decreased in the 6th, 9th, and 12th months after bleaching, and the differences were statistically significant. No significant difference was found in the rebound speed between time points. However, this rate settled after the 9th month, with an average color rebound rate of 30.11% in 20 patients.@*CONCLUSIONS@#The results indicated that internal bleaching could cause a noticeable color change on pulpless teeth. The color rebound after bleaching was mainly caused by lightness (L*), which gradually decreased with time, and it was slightly related to a* and b*. The color of the teeth after internal bleaching rebounded to a certain extent with time, but the color rebound speed became stable from the 9th month. Clinically, secondary internal bleaching can be considered at this time according to whether the colors of the affected tooth and the adjacent tooth are coordinated and depending on the patient's needs.


Assuntos
Humanos , Clareamento Dental/métodos , Dente não Vital/tratamento farmacológico , Cor , Descoloração de Dente/tratamento farmacológico , Dente , Peróxido de Hidrogênio/uso terapêutico , Clareadores Dentários/uso terapêutico
16.
Dental Press J Orthod ; 27(5): e2220325, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36350943

RESUMO

INTRODUCTION: Many patients wearing orthodontic appliances request alterations in the shade of their teeth during orthodontic treatment. OBJECTIVE: This study aimed to evaluate the efficacy of different products for bleaching and whitening under orthodontic brackets. METHODS: Seventy bovine incisors were randomly divided into five groups (n = 14): C) non-whitening toothpaste (control); WTsi) hydrated silica whitening toothpaste; WThp) 2% hydrogen peroxide whitening toothpaste; OB) in-office bleaching; and HB) at-home bleaching. Two buccal surface areas were evaluated using the Easyshade spectrophotometer: under the metal bracket (experimental) and around the bracket (control). The paired t-test, ANOVA, and Tukey tests were applied for statistical analysis. RESULTS: Intragroup comparisons showed that in groups C, WThp and HB, there were statistically significant differences in the enamel color changes (ΔEab) between under and around the bracket areas (C - under bracket = 7.97 ± 2.35, around bracket = 2.86 ± 0.81, p< 0.01; WThp - under bracket = 4.69 ± 2.98, around bracket = 2.05 ± 1.41, p< 0.01; HB - under bracket = 7.41 ± 2.89, around bracket: 9.86 ± 3.32, p= 0.02). Groups WTsi, OB and HB presented similar perception of tooth whiteness (ΔWID) between the tested areas. Intergroup comparisons demonstrated that under the bracket area, the color change (ΔEab) was similar for all groups, except WThp (C = 7.97 ± 2.35; WTsi = 8.54 ± 3.63; WThp = 4.69 ± 2.98; OB = 9.31 ± 4.32; HB = 7.41 ± 2.89; p< 0.01). CONCLUSIONS: The dental color changes were effective for the products tested in groups WTsi, OB and HB in the presence of metallic orthodontic brackets.


Assuntos
Braquetes Ortodônticos , Clareadores Dentários , Clareamento Dental , Animais , Bovinos , Cor , Esmalte Dentário , Peróxido de Hidrogênio , Clareadores Dentários/uso terapêutico , Cremes Dentais
17.
PLoS One ; 17(11): e0277346, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36395262

RESUMO

OBJECTIVE: This clinical trial evaluated the effect of 1.5% potassium oxalate (PO) in controlling sensitivity and color change after at-home tooth whitening. It also evaluated the influence of PO on health-related quality of life (HRQoL) and the degree of patient satisfaction after bleaching treatment. MATERIALS AND METHODS: Fifty volunteers were randomized into two groups (n = 25): At-home bleaching gel with 22% carbamide peroxide for 45 min + placebo gel (GP) or 1.5% PO (GPO) for 10 min. The intensity of tooth sensitivity was assessed daily through the visual analog scale. The color analysis was performed three times: baseline, 21 days, and 1 month after the last application of the whitening gel. The impact of the oral condition on the patient's quality of life (OIDP) was used to measure the impact caused by the whitening treatment in relation to the individuals' ability to carry out their daily activities and its influence on HRQOL. RESULTS: No difference in tooth sensitivity was observed (p > 0.05). In addition, there was no difference in color change between groups (p > 0.05). However, there was an intragroup statistical difference throughout the evaluation period (p <0.05). The OIDP analysis showed a statistical difference between the groups (p > 0.05) and there was no difference between the groups regarding the degree of satisfaction with the bleaching (p > 0.05). CONCLUSIONS: The 1.5% PO was effective in preventing sensitivity and did not interfere with tooth whitening. Desensitizing therapy had a positive impact on quality of life and patient satisfaction.


Assuntos
Sensibilidade da Dentina , Clareadores Dentários , Clareamento Dental , Humanos , Clareamento Dental/efeitos adversos , Qualidade de Vida , Sensibilidade da Dentina/tratamento farmacológico , Clareadores Dentários/uso terapêutico , Ácido Oxálico , Peróxido de Hidrogênio
18.
Oper Dent ; 47(5): 492-502, 2022 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-36121729

RESUMO

OBJECTIVES: To compare the risk and intensity of tooth sensitivity (TS) as well the effectiveness of at-home bleaching using two carbamide peroxide bleaching gels, specifically a novel polymeric nanoparticle gel (experimental) and a commercial gel (Opalescence PF, Ultradent, South Jordan, Utah, USA), applied at two application times. METHODS: This multicenter, triple-blind, and split-mouth randomized controlled trial was conducted on 80 healthy adults with canine teeth that were shade A2 or darker. The participants all used the experimental and the control gels on one side of a tray, depending on the group to which they were allocated, for 30 or 60 minutes per day over four weeks. The absolute risk and intensity of TS were assessed daily using the five-point Numeric Rating Scale and the 0-10 Visual Analogue Scale. Color change was evaluated with shade guide units (ΔSGU) and a digital spectrophotometer (ΔEab, ΔE00, and ΔWid) at baseline and 30 days postbleaching. The risk and intensity of TS was evaluated by the McNemar and the Wilcoxon signed-rank tests, respectively. Color change (ΔSGU, ΔEab, ΔE00, and ΔWid) was evaluated by Mann-Whitney and paired t-tests (α=0.05). RESULTS: No differences in the risk and intensity of TS were observed based on the bleaching gels used and the times of application (p>0.05). Thirty days after bleaching, there was no significant difference in color change, in terms of the bleaching gels used or the application times (p>0.05). CONCLUSION: The novel carbamide peroxide polymeric nanoparticles gel, when applied for 30 or 60 minutes, produced effective color change and a low rate of tooth sensitivity, as compared to the control group.


Assuntos
Sensibilidade da Dentina , Nanopartículas , Clareadores Dentários , Clareamento Dental , Peróxido de Carbamida , Géis , Humanos , Peróxido de Hidrogênio , Clareadores Dentários/uso terapêutico , Resultado do Tratamento
19.
Am J Dent ; 35(4): 191-196, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35986934

RESUMO

PURPOSE: To evaluate the influence of diet and exposure to red wine on the treatment velocity, clinical results, postoperative tooth sensitivity, and patient satisfaction after tooth bleaching. METHODS: 45 subjects undergoing home bleaching with 16% carbamide peroxide (CP) were randomly separated into three groups, depending on the restriction of colored food and the use of a red wine mouthwash. Shades of teeth 11 and 21 were assessed using a digital spectrophotometer (VITA Easy Shade) at T0 (before treatment), T7 (7 days after treatment), T15 (15 days after treatment), and T30 (30 days after treatment). The assessments were verified using the CIELab system (values of L*, a*, and b*) and the change in shade was calculated (ΔE, ΔL, Δa, and Δb). RESULTS: No statistically significant differences in ΔE, ΔL, Δa, and Δb were found between the groups. However, at T7, the group restricted from colored foods without red wine mouthwash had meaningful variations in L*, a*, and b*. Statistically, there was no difference in tooth sensitivity between the groups in the 7- and 15-day periods. Patients in the restricted colored foods without red wine mouthwash group were more satisfied after the end of treatment. CLINICAL SIGNIFICANCE: Tooth bleaching with 16% carbamide peroxide may be performed in subjects with colorant-rich diets without influencing the clinical outcome.


Assuntos
Sensibilidade da Dentina , Clareadores Dentários , Clareamento Dental , Vinho , Peróxido de Carbamida , Cor , Sensibilidade da Dentina/tratamento farmacológico , Sensibilidade da Dentina/prevenção & controle , Dieta , Humanos , Peróxido de Hidrogênio , Antissépticos Bucais , Peróxidos/uso terapêutico , Clareamento Dental/métodos , Clareadores Dentários/uso terapêutico , Ureia/uso terapêutico
20.
Gen Dent ; 70(5): 35-39, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35993931

RESUMO

The aim of this in vitro study was to compare the efficacy and durability of bleaching with diode lasers over a 9-month period. This study evaluated 27 extracted teeth categorized into 3 bleaching groups (n = 9): 940-nm diode laser, 980-nm diode laser, and 40% hydrogen peroxide whitening gel (control). After the baseline color of the teeth was measured using a spectrophotometer, the teeth underwent dental prophylaxis and their color was measured again. Bleaching treatment was then performed. The color of the teeth was measured immediately after bleaching and 1 day (24 hours), 1 week, 1 month, 3 months, 6 months, and 9 months after bleaching. The Commission Internationale de l'Eclairage (CIE) L*a*b* color change (ΔE*) at each timepoint was calculated and compared using repeated-measures analysis of variance. All bleaching techniques effectively whitened the teeth to a clinically perceptible level (ΔE* > 3.3), and there were no statistically significant differences among the groups (P > 0.05). The mean ΔE* values of the laser groups were not significantly different from the mean value of the control group during the 9-month evaluation period (P > 0.05). However, statistically significant differences among the groups were noted when color measurements at the following timepoints were compared: immediately after bleaching vs 1 day; 1 day vs 1 week; and 3 months vs 6 months (P < 0.05). Use of a 940-nm diode laser, 980-nm diode laser, or conventional hydrogen peroxide gel provided equally effective bleaching. The color change remained clinically perceptible throughout the 9-month period.


Assuntos
Clareadores Dentários , Clareamento Dental , Cor , Humanos , Peróxido de Hidrogênio/uso terapêutico , Lasers Semicondutores/uso terapêutico , Espectrofotometria , Clareamento Dental/métodos , Clareadores Dentários/uso terapêutico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...